CB-RE LEDs

Each Routing Engine on the CB-RE (model numbers RE-MX2000-1800X4 and REMX2K-X8-64G) has three LEDs that indicate its status. The LEDs, labeled ONLINE, MASTER, OK/FAIL, are located directly on the faceplate of the CB-RE. Table 1 describes the functions of the Routing Engine interface of the CB-RE. There are three LEDs on the craft interface for each Routing Engine (RE0 and RE1). These LEDs are labeled MASTER, ONLINE, and OFFLINE.

Note:

The GPS LED will display when connecting to an external clocking interface.

The Control Board, part of the host subsystem, has a set of bicolor LEDs that display its status. The LEDs, labeled LINK, GPS, BITS, and UTI are located directly on the faceplate of the CB-RE. Table 1 describes the functions of the Control Board interface of the CB-RE. There are two LEDs on the craft interface for each Control Board–one labeled CB-RE0 (far left) and one labeled CB-RE1 (far right). For more information about the CB-RE and Routing Engine LEDs on the craft interface, see CB-RE LEDs.

Table 1: CB-RE LEDs

Label

Color

State

Description

ONLINE

Green

Blinking

CB-RE is transitioning online.

On steadily

CB-RE is functioning normally.

—

Off

CB-RE is offline.

MASTER

Blue

On steadily

CB-RE is the primary.

OK/FAIL

Red

On steadily

CB-RE has failed.

LINK

Green

On steadily

SFP+ ports (XGE-0 and XGE-1) link connection.

Blinking steadily

Activity on SFP+ ports (XGE-0 and XGE-1).

Yellow

On

No link.

BITS

Green

On steadily

BITS external clocking interface is active.

Yellow

On steadily

BITS external clocking interface has failed.

–

Off

BITS external clocking interface is offline.

GPS

Green

On steadily

GPS external clocking interface is active.

Yellow

On steadily

GPS external clocking interface has failed.

–

Off

GPS external clocking interface is offline.

Figure 1: REMX2K-X8-64G CB-RE LEDsREMX2K-X8-64G CB-RE LEDs
Table 2: REMX2K-X8-64G CB-RE LEDs

Callout from Figure 1

Label

Color

State

Description

1

ONLINE

Green

Blinking

CB-RE is transitioning online.

On steadily

CB-RE is functioning normally.

—

Off

CB-RE is offline.

1

MASTER

Blue

On steadily

CB-RE is the primary.

1

OK/FAIL

Yellow

Off

RE is functioning normally.

On steadily

RE has failed.

2

DISK1

Green

Blinking

Indicates presence of disk activity.

-

Off

There is no disk activity.

2

DISK2

Green

Blinking

Indicates presence of disk activity.

-

Off

There is no disk activity.

3

LINK

Green

On steadily

SFP+ ports (XGE0 and XGE1) links are active.

Blinking steadily

Activity on the SFP+ ports (XGE0 and XGE1).

Yellow

On

No link.

4

Unlabeled (top LED)

Green

On steadily

BITS external clocking interface (on EXTCLK-0 port) is active.

Yellow

On steadily

BITS external clocking interface (on EXTCLK-0 port) has failed.

–

Off

BITS external clocking interface (on EXTCLK-0 port) is offline.

4

Unlabeled (center LED)

Green

On steadily

GPS external clocking interface (on EXTCLK-0 port) is active.

Yellow

On steadily

GPS external clocking interface (on EXTCLK-0 port) has failed.

–

Off

GPS external clocking interface (on EXTCLK-0 port) is offline.

4

Unlabeled (bottom LED)

Green

On steadily

UTI external clocking interface (on EXTCLK-0 port) is active.

Yellow

On steadily

UTI external clocking interface (on EXTCLK-0 port) has failed.

–

Off

UTI external clocking interface (on EXTCLK-0 port) is offline.

5

BITS

Green

On steadily

BITS external clocking interface (on EXTCLK-1 port) is active.

Yellow

On steadily

BITS external clocking interface (on EXTCLK-1 port) has failed.

–

Off

BITS external clocking interface (on EXTCLK-1 port) is offline.

5

GPS

Green

On steadily

GPS external clocking interface (on EXTCLK-1 port) is active.

Yellow

On steadily

GPS external clocking interface (on EXTCLK-1 port) has failed.

–

Off

GPS external clocking interface (on EXTCLK-1 port) is offline.

5

UTI

Green

On steadily

UTI external clocking interface (on EXTCLK-1 port) is active.

Yellow

On steadily

UTI external clocking interface (on EXTCLK-1 port) has failed.

–

Off

UTI external clocking interface (on EXTCLK-1 port) is offline.

6

OK/FAIL

Red

On steadily

CB has failed.