Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    maintenance-domain

    Syntax

    maintenance-domain domain-name {bridge-domain name <vlan-id [ vlan-ids ]>;instance vpls-instance-name;level number;maintenance-association ma-name {protect-maintenance-association protect-ma-name;remote-maintenance-association remote-ma-name;short-name-format (character-string | vlan | 2octet | rfc-2685-vpn-id);continuity-check {hold-interval minutes;interval (10m | 10s | 1m | 1s| 100ms);loss-threshold number}mep mep-id {auto-discovery;direction (up | down);interface interface-name (protect | working);lowest-priority-defect (all-defects | err-xcon | mac-rem-err-xcon | no-defect | rem-err-xcon | xcon );priority number;remote-mep mep-id {action-profile profile-name;sla-iterator-profile profile-name {data-tlv-size size;iteration-count count-value;priority priority-value;}}}mip-half-function(none | default | explicit);name-format (character-string | none | dns | mac+2oct);}virtual-switch name { bridge-domain name <vlan-id [ vlan-ids ]>;}}

    Hierarchy Level

    Release Information

    Statement introduced in Junos OS Release 8.4.

    Statement introduced in Junos OS Release 12.1X48 for PTX Series Packet Transport Switches.

    Description

    Configure the name of the maintenance domain in IEEE-compliant format.

    Options

    domain-name—Name of the maintenance domain.

    The remaining statements are explained separately.

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration.