Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    show interfaces ps0 (Pseudowire Subscriber Interfaces)

    Syntax

    show interfaces ps0<brief | detail | extensive | terse>

    Release Information

    Command introduced at Junos OS Release 13.1.

    Description

    Display status information about the pseudowire subscriber interface.

    Options

    brief | detail | extensive | terse
    —

    (Optional) Display the specified level of output.

    Required Privilege Level

    view

    List of Sample Output

    show interfaces ps0

    Output Fields

    Table 1 lists the output fields for the show interfaces ps0 command. Output fields are listed in the approximate order in which they appear.

    Table 1: show interfaces ps0 Output Fields

    Field Name

    Field Description

    Level of Output

    Physical Interface 

    Physical interface

    Name of the physical interface.

    brief detail extensive none

    Enabled

    State of the interface. Possible values are described in the “Enabled Field” section under Common Output Fields Description.

    brief detail extensive none

    Interface index

    Physical interface index number, which reflects its initialization sequence.

    detail extensive none

    SNMP ifIndex

    SNMP index number for the physical interface.

    detail extensive none

    Type

    Physical interface type (Software-Pseudo).

    brief detail extensive none

    Link-level type

    Encapsulation being used on the physical interface.

    brief detail extensive

    MTU

    MTU size on the physical interface.

    brief detail extensive

    Clocking

    Reference clock source. It can be Internal or External.

    brief detail extensive

    Speed

    Speed at which the interface is running.

    brief detail extensive

    Device flags

    Information about the physical device. Possible values are described in the “Device Flags” section under Common Output Fields Description.

    brief detail extensive none

    Interface flags

    Information about the interface. Possible values are described in the “Interface Flags” section under Common Output Fields Description.

    brief detail extensive none

    Current address

    Configured MAC address.

    detail extensive none

    Hardware address

    MAC address of the hardware.

    detail extensive none

    Last flapped

    Date, time, and how long ago the interface went from down to up or up to down. The format is Last flapped: year-month-day hours:minutes:seconds: timezone (hours:minutes:seconds ago). or Never. For example, Last flapped: 2002-04-26 10:52:40 PDT (04:33:20 ago).

    detail extensive none

    input packets

    Number of packets received on the logical interface.

    detail extensive none

    output packets

    Number of packets transmitted on the logical interface.

    detail extensive none

    Logical Interface 

    Logical interface

    Name of the logical interface.

    brief detail extensive none

    Index

    Logical interface index number (which reflects its initialization sequence).

    detail extensive none

    SNMP ifIndex

    Logical interface SNMP interface index number.

    detail extensive none

    Flags

    Information about the logical interface. Possible values are described in the “Logical Interface Flags” section under Common Output Fields Description.

    brief detail extensive none

    Encapsulation

    Type of encapsulation configured on the logical interface.

    brief extensive none

    Input packets

    Number of packets received on the logical interface.

    none

    Output packets

    Number of packets transmitted on the logical interface.

    none

    Protocol

    Protocol family configured on the logical interface.

    detail extensive none

    MTU

    MTU size on the logical interface.

    detail extensive none

    Flags

    Information about the protocol family flags. Possible values are described in the “Family Flags” section under Common Output Fields Description.

    detail extensive none

    Addresses, Flags

    Information about the addresses configured for the protocol family. Possible values are described in the “Addresses Flags” section under Common Output Fields Description.

    detail extensive none

    Destination

    IP address of the remote side of the connection.

    detail extensive none

    Local

    IP address of the logical interface.

    detail extensive terse none

    Broadcast

    Broadcast address.

    detail extensive none

    Sample Output

    show interfaces ps0

    user@host> show interfaces ps0
    Physical interface: ps0, Enabled, Physical link is Up
     Interface index: 166, SNMP ifIndex: 658
     Type: Software-Pseudo, Link-level type: 90, MTU: 1518, Clocking: 1, Speed: 800mbps
     Device flags : Present Running
     Interface flags: Point-To-Point Internal: 0x4000
     Current address: 00:1d:b5:a8:19:4a, Hardware address: 00:1d:b5:a8:19:4a
     Last flapped : Never
      Input packets : 0
      Output packets: 0
    
     Logical interface ps0.0 (Index 74) (SNMP ifIndex 656)
      Flags: Point-To-Point 0x4000 Encapsulation: Ethernet-CCC
      Input packets : 482
      Output packets: 0
      Protocol ccc, MTU: 1518
       Flags: Is-Primary
    
     Logical interface ps0.1 (Index 78) (SNMP ifIndex 665)
      Flags: Point-To-Point 0x4000 VLAN-Tag [ 0x8100.100 ] Encapsulation: ENET2
      Input packets : 0
      Output packets: 482
      Protocol inet, MTU: 1500
       Flags: Sendbcast-pkt-to-re
        Addresses, Flags: Is-Preferred Is-Primary
         Destination: 20.0.0/24, Local: 20.0.0.1, Broadcast: 20.0.0.255
    
     Logical interface ps0.32767 (Index 75) (SNMP ifIndex 692)
      Flags: Point-To-Point 0x4000 VLAN-Tag [ 0x0000.0 ] Encapsulation: ENET2
      Input packets : 0
      Output packets: 0

    Published: 2013-02-11