    Example: Consolidating a Layer 2 VPN Network

    In this configuration example, a Layer 2 VPN network topology is reduced and simplified by replacing two M320 routers at the provider edge (PE) of the network with a single platform. The configuration for the consolidated Layer 2 VPN topology is described in the following sections:

    Requirements

    This example requires the following hardware and software components:

    • Junos OS Release 9.1 or later
    • One JCS1200 platform with Routing Engines in slots 4, 5, and 6
    • One T640 router with FPCs in slots 4 and 5

    Overview and Topology

    In a typical Layer 2 VPN topology, a customer edge (CE) router is located on each customer site, providing an Ethernet interface between the customer LAN and the provider core network. Provider (P) routers are located in the core of the provider network, and provider edge (PE) routers sit at the edge of the network.

    Figure 1 illustrates a typical Layer 2 VPN topology, with T640 routers as P routers, M320 routers as PE routers, and MX Series Ethernet Services routers as CE routers. The service provider uses a separate PE router for each customer.

    Figure 1: Typical Layer 2 VPN Network Topology

    Typical Layer 2
VPN Network Topology

    By replacing the two M320 routers with the JCS1200 chassis interconnected with the T640 router, the service provider simplifies and consolidates the network at the provider edge. One platform supports both customer networks through the creation of PSDs, as shown in Figure 2.

    Figure 2: Consolidated Layer 2 VPN Network Topology

    Consolidated
Layer 2 VPN Network Topology

    Configuration

    Table 1 provides the chassis parameters required for the JCS1200 platform and the T640 router for each PSD.

    Table 1: Chassis Parameters

    PSD

    JCS1200 Platform

    T640 Routing Node

    PSD1

    Routing Engine in slot 4

    FPC in slot 4 (with PICs supporting Fast Ethernet and SONET interfaces)

    PSD2

    Routing Engines in slots 5 and 6

    FPC in slot 5 (with PICs supporting Fast Ethernet and SONET interfaces)

    The configuration for the consolidated Layer 2 VPN topology is described in the following sections:

    JCS1200 Platform Configuration

    Step-by-Step Procedure

    To configure the parameters required for the Routing Engines in the JCS chassis:

    1. Log in to the JCS management module CLI.
    2. Configure the Routing Engine that is part of PSD1. The Routing Engine in slot 4 of the JCS chassis is the master Routing Engine. There is no backup Routing Engine.

      To configure the Routine Engine in slot 4, issue the following command:

      system> baydata —b 04 —data “V01–JCS01–SD01–PSD01–REP04–REB00–PRDT640”
      OK

      The baydata command specifies the target as a bay blade (-b), identifies the blade (Routing Engine) in slot 04, and specifies the following parameters:

      • V01—Product version, which is 01.
      • JCS01—JCS platform identifier, which is 01.
      • SD01—RSD identifier, which is 01.
      • PSD01–PSD identifier, which is 01.
      • REP04—Slot in which the primary (or master) Routing Engine resides, which is 04.
      • REB00—Slot in which the backup Routing Engine resides. 00 indicates that there is no backup Routing Engine.
      • PRDT640—Juniper Networks router product, which is a T640 router.
    3. Configure the baydata command parameters for the Routing Engines that are part of PSD2. The Routing Engine in slot 5 is the master, whereas the Routing Engine in slot 6 is the backup Routing Engine.
      1. To configure the Routing Engine in slot 5, issue the following command:
        system> baydata —b 05 —data “V01–JCS01–SD01–PSD02–REP05–REB06–PRDT640”
        OK

        The baydata command specifies the target as a bay blade (-b), identifies the blade (Routing Engine) in slot 05, and specifies the following parameters:

        • V01—Product version. Junos OS Release 9.1 supports only the value of 01.
        • JCS01—JCS platform identifier of 01. Junos OS Release 9.1 supports only the value of 01.
        • SD01—RSD identifier, which is 01.
        • PSD02–PSD identifier, which is 02.
        • REP05—Slot in which the primary (or master) Routing Engine resides, which is 05.
        • REB06—Slot in which the backup Routing Engine resides, which is 06.
        • PRDT640—Juniper Networks router product, which is a T640 router.
      2. To configure the Routing Engine in slot 6, issue the following command:
        system> baydata —b 06 —data “V01–JCS01–SD01–PSD02–REP05–REB06–PRDT640”
        OK

        The baydata command specifies the target as a bay blade (-b), identifies the blade (Routing Engine) in slot 06, and specifies the following parameters:

        • V01—Product version, which is 01.
        • JCS01—JCS platform identifier, which is 01.
        • SD01—RSD identifier, which is 01.
        • PSD02–PSD identifier, which is 02.
        • REP05—Slot in which the primary (or master) Routing Engine resides, which is 05.
        • REB06—Slot in which the backup Routing Engine resides, which is 06.
        • PRDT640—Juniper Networks router product, which is a T640 router.

    Results

    Display the results of the configuration:

    system> baydata
    Bay  Status            Definition
    1    No blade present
    2    No blade present
    3    No blade present
    4    Supported         V01-JCS01-SD01-PSD01-REP04-REB00-PRDT640
    5    Supported         V01-JCS01-SD01-PSD02-REP05-REB06-PRDT640
    6    Supported         V01-JCS01-SD01-PSD02-REP05-REB06-PRDT640
    7    No blade present
    8    No blade present
    9    No blade present
    10   No blade present
    11   No blade present
    12   No blade present

    RSD Configuration

    Step-by-Step Procedure

    To configure the RSD and create the PSDs on the master Routing Engine in the T640 router:

    1. At the [edit chassis system-domains] hierarchy level of the Junos OS CLI, include the root-domain-id 1 statement to identify the RSD.
    2. At the [edit chassis system-domains] hierarchy level, include the protected-system-domains psd1 statement to create PSD1.
    3. At the [edit chassis system-domains protected-system-domains psd1] hierarchy level:
      1. Include the fpcs 4 statement to assign the FPC in slot 4 to PSD1.
      2. Include the control-system-id 1 statement to identify the JCS1200 platform.
      3. Include the control-slot-numbers 4 statement to assign the Routing Engine in slot 4 in the JCS chassis to PSD1.

    4. At the [edit chassis system-domains] hierarchy level, include the protected-system-domains psd2 statement to create PSD2.
    5. At the [edit chassis system-domains protected-system-domains psd2] hierarchy level:
      1. Include the fpcs 5 statement to assign the FPC in slot 5 to PSD2.
      2. Include the control-system-id 1 statement to identify the JCS1200 platform.
      3. Include the control-slot-numbers 5 control-slot-numbers 6 statement to assign the Routing Engines in slot 5 and slot 6 in the JCS chassis to PSD2.

    Results

    Display the results of the configuration:

    chassis {system-domains {root-domain-id 1;protected-system-domains {psd1 {fpcs 4;control-system-id 1;control-slot-numbers 4;}psd2 {fpcs 5;control-system-id 1;control-slot-numbers [5 6];}}}}

    PSD1 Configuration

    Step-by-Step Procedure

    The configuration for PSD1 is much the same as the configuration that was running on the T640 router in the original VPN network topology before the consolidation of two routers into a single platform.

    The key difference is the management configuration. To configure the unique parameters for PSD1:

    1. Configure the following statements at the [edit groups re0 system] hierarchy level:
      1. Include the host-name customer-a statement to configure the hostname for PSD1.
      2. Include the backup-router 192.168.71.254 statement to configure a backup router. The backup router should be directly connected to the local routing platform by way of the management interface.
      3. Include the address 192.168.66.240/21 statement at the [edit interfaces fxp0 unit 0 family inet] hierarchy level to configure the management interface.

    Results

    Display the results of the configuration:

    re0 {system {host-name customer-a;backup-router 192.168.71.254 destination [ 172.16.0.0/12 192.168.0.0/16 207.17.136.192/32 10.9.0.0/16 10.10.0.0/16 10.13.10.0/23 10.84.0.0/16 10.5.0.0/16 10.6.128.0/17 192.168.102.0/23 207.17.136.0/24 10.209.0.0/16 10.227.0.0/16 10.150.0.0/16 10.157.64.0/19 10.204.0.0/16 ];}interfaces {fxp0 {unit 0 {family inet {address 192.168.66.240/21;}}}}}interfaces {fe-0/2/3 {unit 0 {family inet {address 10.6.1.1/30;}family iso;family mpls;}}so-4/0/3 {encapsulation frame-relay-ccc;unit 2 {encapsulation frame-relay-ccc;dlci 512;}}fe-4/3/0 {unit 0 {family inet {address 10.5.1.2/30;}family iso;family mpls;}}}routing-options {autonomous-system 65299;confederation 702 members [ 65299 65235 65240 65269 ];}protocols {mpls {interface all;}bgp {group ibgp {type internal;local-address 10.255.171.124;import match-all;family l2vpn {signaling;}export match-all;neighbor 10.255.171.125;}}isis {interface fe-4/2/3.0 {level 2 metric 10;level 1 disable;}interface fe-4/3/0.0 {level 2 metric 10;level 1 disable;}interface all;interface fxp0.0 {disable;}interface lo0.0 {passive;}}ldp {interface all;interface lo0.0;}}policy-options {policy-statement frame-relay-vpn-export {term a {then {community add frame-relay-vpn-comm;accept;}}term b {then reject;}}policy-statement frame-relay-vpn-import {term a {from {protocol bgp;community frame-relay-vpn-comm;}then accept;}term b {then reject;}}policy-statement match-all {then accept;}community frame-relay-vpn-comm members target:65299:400;}routing-instances {frame-relay-vpn {instance-type l2vpn;interface so-4/0/3.2;route-distinguisher 10.255.171.124:4;vrf-import frame-relay-vpn-import;vrf-export frame-relay-vpn-export;protocols {l2vpn {encapsulation-type frame-relay;site 2 {site-identifier 2;interface so-4/0/3.2 {remote-site-id 1;}}}}}}

    PSD2 Configuration

    Step-by-Step Procedure

    The configuration for PSD2 is much the same as the configuration that was running on the T640 router in the original VPN network topology before the consolidation of two routers into a single platform.

    The key difference is the management configuration. To configure the unique parameters for PSD2:

    1. Configure the following statements at the [edit system re0] hierarchy level:
      1. Include the host-name customer-b statement to configure the hostname for the master Routing Engine (re0) on PSD2.
      2. Include the backup-router 192.168.71.254 statement to configure a backup router. The backup router should be directly connected to the local routing platform by way of the management interface.
      3. Include the address 192.168.66.240/21 statement at the [edit interfaces fxp0 unit 0 family inet] hierarchy level to configure the fxp0 management interface.
    2. Configure the backup Routing Engine parameters by including the following statements at the [edit system re1] hierarchy level:
      1. Include the host-name customer-b1 statement to configure the hostname for the backup Routing Engine (re1) on PSD2.
      2. Include the backup-router 192.168.71.254 statement to configure a backup router. The backup router should be directly connected to the local routing platform by way of the management interface.
      3. Include the address 192.168.66.242/21 statement at the [edit interfaces fxp0 unit 0 family inet] hierarchy level to configure the fxp0 management interface.

    Results

    Display the results of the configuration:

    re0 {system {host-name customer-b;backup-router 192.168.71.254 destination [ 172.16.0.0/12 192.168.0.0/16 207.17.136.192/32 10.9.0.0/16 10.10.0.0/16 10.13.10.0/23 10.84.0.0/16 10.5.0.0/16 10.6.128.0/17 192.168.102.0/23 207.17.136.0/24 10.209.0.0/16 10.227.0.0/16 10.150.0.0/16 10.157.64.0/19 10.204.0.0/16 ];}interfaces {fxp0 {unit 0 {family inet {address 192.168.66.242/21;}}}}}re1 {system {host-name customer-b1;backup-router 192.168.71.254 destination [ 172.16.0.0/12 192.168.0.0/16 207.17.136.192/32 10.9.0.0/16 10.10.0.0/16 10.13.10.0/23 10.84.0.0/16 10.5.0.0/16 10.6.128.0/17 192.168.102.0/23 207.17.136.0/24 10.209.0.0/16 10.227.0.0/16 10.150.0.0/16 10.157.64.0/19 10.204.0.0/16 ];}interfaces {fxp0 {unit 0 {family inet {address 192.168.66.241/21;}}}}}interfaces {fe-5/1/1 {unit 0 {family inet {address 10.5.1.1/30;}family iso;family mpls;}}fe-5/1/2 {unit 0 {family inet {address 10.8.1.1/30;}family iso;family mpls;}}so-5/3/0 {encapsulation frame-relay-ccc;unit 1 {encapsulation frame-relay-ccc;dlci 512;}}}routing-options {autonomous-system 65299;confederation 702 members [ 65299 65235 65240 65269 ];}protocols {mpls {interface all;}bgp {group ibgp {type internal;local-address 10.255.171.125;import match-all;family l2vpn {signaling;}export match-all;neighbor 10.255.171.124;}}isis {interface fe-5/1/1.0 {level 2 metric 10;level 1 disable;}interface fe-5/1/2.0 {level 2 metric 10;level 1 disable;}interface all;interface fxp0.0 {disable;}interface lo0.0 {passive;}}ldp {interface all;interface lo0.0;}}policy-options {policy-statement frame-relay-vpn-export {term a {then {community add frame-relay-vpn-comm;accept;}}term b {then reject;}}policy-statement frame-relay-vpn-import {term a {from {protocol bgp;community frame-relay-vpn-comm;}then accept;}term b {then reject;}}policy-statement match-all {then accept;}community frame-relay-vpn-comm members target:65299:400;}routing-instances {frame-relay-vpn {instance-type l2vpn;interface so-5/3/0.1;route-distinguisher 10.255.171.125:4;vrf-import frame-relay-vpn-import;vrf-export frame-relay-vpn-export;protocols {l2vpn {encapsulation-type frame-relay;site 1 {site-identifier 1;interface so-5/3/0.1 {remote-site-id 2;}}}}}}

    Verification

    Verify that the two PSDs are configured and operating properly:

    Verifying Configured PSDs

    Purpose

    Verify that PSD1 and PSD2 are configured and online.

    Action

    On the RSD, issue the show chassis psd command.

    {master}
    user@host> show chassis psd
    PSD  Description   State        Uptime
    1                  Online        5 days, 19 hours, 16 minutes, 16 seconds
    2                  Online        5 days, 18 hours, 12 minutes, 11 seconds

    Meaning

    The example shows that the PSDs are configured and online.

    Verifying PSD Hardware

    Purpose

    Display information about the FPCs and Routing Engines that are part of each PSD.

    Action

    On each PSD, issue the show chassis hardware command.

    The following example displays the hardware components belonging to PSD1:

    user@psd1> show chassis hardware
    rsd-re0:
    --------------------------------------------------------------------------
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                                S19068            T640
    Midplane         REV 04   710-002726   AX5666            T640 Backplane
    FPM GBUS         REV 02   710-002901   HE3251            T640 FPM Board
    FPM Display      REV 02   710-002897   HE7860            FPM Display
    CIP              REV 05   710-002895   HC0474            T Series CIP
    PEM 1            Rev 03   740-002595   MH15367           Power Entry Module
    SCG 0            REV 04   710-003423   HF6042            T640 Sonet Clock Gen.
    SCG 1            REV 11   710-003423   HW7765            T640 Sonet Clock Gen.
    Routing Engine 0 REV 04   740-014082   1000660098        RE-A-2000
    Routing Engine 1 REV 01   740-005022   210865700324      RE-3.0
    CB 0             REV 06   710-007655   WE9377            Control Board (CB-T)
    CB 1             REV 06   710-007655   WE9379            Control Board (CB-T)
    FPC 4            REV 02   710-002385   HC0619            FPC Type 2
      CPU            REV 06   710-001726   HB1916            FPC CPU
      MMB 1          REV 03   710-004047   HE3195            MMB-288mbit
      ICBM           REV 04   710-003384   HC0377            FPC ICBM
      PPB 0          REV 02   710-003758   HC0585            PPB Type 2
      PPB 1          REV 02   710-003758   HC0574            PPB Type 2
    SPMB 0           REV 10   710-003229   WE9582            T Series Switch CPU
    SPMB 1           REV 10   710-003229   WE9587            T Series Switch CPU
    SIB 0            REV 05   750-005486   HV8445            SIB-I8-F16
    SIB 1            REV 05   750-005486   HW2650            SIB-I8-F16
    SIB 2            REV 05   750-005486   HW7041            SIB-I8-F16
    SIB 3            REV 05   750-005486   HV4274            SIB-I8-F16
    SIB 4            REV 05   750-005486   HV8464            SIB-I8-F16
    Fan Tray 0                                               Front Top Fan Tray
    Fan Tray 1                                               Front Bottom Fan Tray
    Fan Tray 2                                               Rear Fan Tray
    
    psd1-re0:
    --------------------------------------------------------------------------
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                   740-023156   SNJCSJCSAC00      JCS1200 AC Chassis
    Routing Engine 0 REV 01   740-023157   SNBLJCSAC004      RE-JCS1200-1x2330
    

    The following example displays the hardware components belonging to PSD2:

    user@psd2> show chassis hardware
    rsd-re0:
    --------------------------------------------------------------------------
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                                S19068            T640
    Midplane         REV 04   710-002726   AX5666            T640 Backplane
    FPM GBUS         REV 02   710-002901   HE3251            T640 FPM Board
    FPM Display      REV 02   710-002897   HE7860            FPM Display
    CIP              REV 05   710-002895   HC0474            T Series CIP
    PEM 1            Rev 03   740-002595   MH15367           Power Entry Module
    SCG 0            REV 04   710-003423   HF6042            T640 Sonet Clock Gen.
    SCG 1            REV 11   710-003423   HW7765            T640 Sonet Clock Gen.
    Routing Engine 0 REV 04   740-014082   1000660098        RE-A-2000
    Routing Engine 1 REV 01   740-005022   210865700324      RE-3.0
    CB 0             REV 06   710-007655   WE9377            Control Board (CB-T)
    CB 1             REV 06   710-007655   WE9379            Control Board (CB-T)
    FPC 5            REV 01   710-010233   HM4187            E-FPC Type 1
      CPU            REV 01   710-010169   HS9939            FPC CPU-Enhanced
      MMB 1          REV 01   710-010171   HR0833            MMB-288mbit
    SPMB 0           REV 10   710-003229   WE9582            T Series Switch CPU
    SPMB 1           REV 10   710-003229   WE9587            T Series Switch CPU
    SIB 0            REV 05   750-005486   HV8445            SIB-I8-F16
    SIB 1            REV 05   750-005486   HW2650            SIB-I8-F16
    SIB 2            REV 05   750-005486   HW7041            SIB-I8-F16
    SIB 3            REV 05   750-005486   HV4274            SIB-I8-F16
    SIB 4            REV 05   750-005486   HV8464            SIB-I8-F16
    Fan Tray 0                                               Front Top Fan Tray
    Fan Tray 1                                               Front Bottom Fan Tray
    Fan Tray 2                                               Rear Fan Tray
    
    psd2-re0:
    --------------------------------------------------------------------------
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                   740-023156   SNJCSJCSAC00      JCS1200 AC Chassis
    Routing Engine 0 REV 01   740-023157   SNBLJCSAC006      RE-JCS1200-1x2330
    Routing Engine 1 REV 01   740-023157   SNBLJCSAC005      RE-JCS1200-1x2330

    Meaning

    In the command output, the FPC that belongs to the PSD is displayed under the rsd-re0: field heading. The Routing Engines on the JCS chassis that belong to the PSD are displayed under the psd2-re0: heading.

    Verifying PSD Routing Engine Information

    Purpose

    Display detailed information about the Routing Engines assigned to each PSD.

    Action

    On each PSD, issue the show chassis routing-engine command.

    The following example displays detailed information about the Routing Engine assigned to PSD1.

    user@psd1> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Physical Slot                  4
        Current state                  Master
        Election priority              Master (default)
        DRAM                     13312 MB
        Memory utilization          10 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     0 percent
          Interrupt                  0 percent
          Idle                     100 percent
        Model                          RE-JCS1200-1x2330
        Serial ID                      SNBLJCSAC004
        Start time                     2008-03-30 03:19:49 PDT
        Uptime                         11 hours, 46 minutes, 24 seconds
        Load averages:                 1 minute   5 minute  15 minute
                                           0.00       0.00       0.00

    The following example displays detailed information about the Routing Engines assigned to PSD2.

    user@psd2> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Physical Slot                  6
        Current state                  Master
        Election priority              Master (default)
        DRAM                     13312 MB
        Memory utilization          10 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     0 percent
          Interrupt                  0 percent
          Idle                     100 percent
        Model                          RE-JCS1200-1x2330
        Serial ID                      SNBLJCSAC006
        Start time                     2008-03-30 03:25:43 PDT
        Uptime                         11 hours, 49 minutes, 30 seconds
        Load averages:                 1 minute   5 minute  15 minute
                                           0.00       0.00       0.00
    Routing Engine status:
      Slot 1:
        Physical Slot                  5
        Current state                  Backup
        Election priority              Backup (default)
        DRAM                     13312 MB
        Memory utilization           9 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     0 percent
          Interrupt                  0 percent
          Idle                     100 percent
        Model                          RE-JCS1200-1x2330
        Serial ID                      SNBLJCSAC005
        Start time                     2008-03-30 03:25:40 PDT
        Uptime                         11 hours, 49 minutes, 36 seconds

    Meaning

    The Physical Slot field displays the JCS chassis slot number in which each Routing Engine is installed.

    Verifying PSD Ethernet Switch Statistics

    Purpose

    Display the Ethernet switch statistics for each PSD.

    Action

    On each PSD, issue the show chassis ethernet-switch statistics command.

    The following example displays information about the Ethernet switch statistics for PSD1:

    user@psd1> show chassis ethernet-switch statistics
    Statistics for switch[1] port INT4 connected to fpx0:
      TX Octets                 3295346375
      TX Unicast Packets        47634559
      TX Multicast Packets      1848912
      TX Broadcast Packets      28900124
      Tx Discards               0
      TX Errors                 0
      RX Octets                 1393157883
      RX Unicast Packets        25671001
      RX Multicast Packets      453
      RX Broadcast Packets      1568098
      RX Discards               1539
      RX Errors                 0
      RX Unknown Protocol       0
      Link State Changes        209
    Statistics for switch[1] port EXT1 connected to RSD 1:
      TX Octets                 2205898607
      TX Unicast Packets        23928658
      TX Multicast Packets      412974
      TX Broadcast Packets      4848743
      Tx Discards               0
      TX Errors                 0
      RX Octets                 2391964542
      RX Unicast Packets        26419568
      RX Multicast Packets      226
      RX Broadcast Packets      6025807
      RX Discards               8
      RX Errors                 4
      RX Unknown Protocol       0
      Link State Changes        113
    Statistics for switch[1] port EXT6 connected to external management:
      TX Octets                 1528646621
      TX Unicast Packets        7591565
      TX Multicast Packets      112
      TX Broadcast Packets      6025
      Tx Discards               0
      TX Errors                 0
      RX Octets                 509146577
      RX Unicast Packets        30206303
      RX Multicast Packets      3036487
      RX Broadcast Packets      12226460
      RX Discards               18650
      RX Errors                 6
      RX Unknown Protocol       0
      Link State Changes        1
    Statistics for switch[2] port INT4 connected to fpx1:
      TX Octets                 3973176699
      TX Unicast Packets        27784685
      TX Multicast Packets      90293282
      TX Broadcast Packets      35160560
      Tx Discards               0
      TX Errors                 0
      RX Octets                 2278093260
      RX Unicast Packets        10421370
      RX Multicast Packets      496
      RX Broadcast Packets      1881084
      RX Discards               1936
      RX Errors                 0
      RX Unknown Protocol       0
      Link State Changes        231
    Statistics for switch[2] port EXT1 connected to RSD 1:
      TX Octets                 3175062867
      TX Unicast Packets        4961873
      TX Multicast Packets      509882
      TX Broadcast Packets      5622328
      Tx Discards               0
      TX Errors                 0
      RX Octets                 478994886
      RX Unicast Packets        49004
      RX Multicast Packets      251
      RX Broadcast Packets      7419709
      RX Discards               12
      RX Errors                 6
      RX Unknown Protocol       0
      Link State Changes        129
    Statistics for switch[2] port EXT6 connected to external management:
      TX Octets                 778154
      TX Unicast Packets        4244
      TX Multicast Packets      73
      TX Broadcast Packets      769
      Tx Discards               0
      TX Errors                 0
      RX Octets                 723965940
      RX Unicast Packets        43991082
      RX Multicast Packets      91767677
      RX Broadcast Packets      15655861
      RX Discards               24442638
      RX Errors                 3331664
      RX Unknown Protocol       0
      Link State Changes        1

    The following example displays information about the Ethernet switch statistics for PSD2:

    user@psd2> show chassis ethernet-switch statistics
    Statistics for switch[1] port INT6 connected to fpx0:
      TX Octets                 2686108265
      TX Unicast Packets        45820458
      TX Multicast Packets      1849567
      TX Broadcast Packets      28901148
      Tx Discards               0
      TX Errors                 0
      RX Octets                 3814661840
      RX Unicast Packets        23875023
      RX Multicast Packets      364
      RX Broadcast Packets      1578993
      RX Discards               1492
      RX Errors                 0
      RX Unknown Protocol       0
      Link State Changes        151
    Statistics for switch[1] port EXT1 connected to RSD 1:
      TX Octets                 2206358846
      TX Unicast Packets        23930762
      TX Multicast Packets      413155
      TX Broadcast Packets      4850581
      Tx Discards               0
      TX Errors                 0
      RX Octets                 2392164387
      RX Unicast Packets        26421668
      RX Multicast Packets      226
      RX Broadcast Packets      6026725
      RX Discards               8
      RX Errors                 4
      RX Unknown Protocol       0
      Link State Changes        113
    Statistics for switch[1] port EXT6 connected to external management:
      TX Octets                 1528692454
      TX Unicast Packets        7591911
      TX Multicast Packets      112
      TX Broadcast Packets      6027
      Tx Discards               0
      TX Errors                 0
      RX Octets                 510609656
      RX Unicast Packets        30209066
      RX Multicast Packets      3037753
      RX Broadcast Packets      12229518
      RX Discards               18650
      RX Errors                 6
      RX Unknown Protocol       0
      Link State Changes        1
    Statistics for switch[2] port INT6 connected to fpx1:
      TX Octets                 3938845805
      TX Unicast Packets        27450378
      TX Multicast Packets      90293642
      TX Broadcast Packets      35156025
      Tx Discards               0
      TX Errors                 0
      RX Octets                 2016108068
      RX Unicast Packets        9832240
      RX Multicast Packets      448
      RX Broadcast Packets      1897002
      RX Discards               1844
      RX Errors                 0
      RX Unknown Protocol       0
      Link State Changes        195
    Statistics for switch[2] port EXT1 connected to RSD 1:
      TX Octets                 3175192403
      TX Unicast Packets        4961873
      TX Multicast Packets      510063
      TX Broadcast Packets      5624171
      Tx Discards               0
      TX Errors                 0
      RX Octets                 479053702
      RX Unicast Packets        49004
      RX Multicast Packets      251
      RX Broadcast Packets      7420628
      RX Discards               12
      RX Errors                 6
      RX Unknown Protocol       0
      Link State Changes        129
    Statistics for switch[2] port EXT6 connected to external management:
      TX Octets                 778154
      TX Unicast Packets        4244
      TX Multicast Packets      73
      TX Broadcast Packets      769
      Tx Discards               0
      TX Errors                 0
      RX Octets                 732481038
      RX Unicast Packets        44041821
      RX Multicast Packets      91768932
      RX Broadcast Packets      15658928
      RX Discards               24443758
      RX Errors                 3331666
      RX Unknown Protocol       0
      Link State Changes        1
    

    Meaning

    In the output for PSD1:

    • INT4 provides the internal connection between the Routing Engine in slot 4 and the JCS switch module.
    • EXT1 provides the connection between the JCS switch module and the RSD.
    • EXT6 provides the connection between the JCS switch module and the management ports on each Routing Engine in the JCS chassis.

    In the output for PSD2:

    • INT6 provides the internal connection between the master Routing Engine in slot 6 and the JCS switch module.
    • EXT1 provides the connection between the JCS switch module and the RSD.
    • EXT6 provides the connection between the JCS switch module and the management ports on each Routing Engine in the JCS chassis.
     