    SONET/SDH RFC 2615 Support Overview

    RFC 2615, PPP over SONET/SDH, requires certain C2 header byte and FCS settings that vary from the default values configured in accordance with RFC 1619 (the previous version of RFC 2615). The newer values are optimized for stronger error detection, especially when combined with payload scrambling at higher bit rate links.

    Table 1 shows the older (RFC 1619) and newer (RFC 2615) values, together with the Juniper Networks default values.

    Table 1: SONET/SDH Default Settings

    Value

    RFC 1619

    Default

    RFC 2615

    SONET/SDH C2 header byte

    0XCF

    0XCF

    0X16

    Frame checksum (bit)

    16

    16

    32

    Payload scrambling

    n/a

    Enabled

    Enabled