    Guidelines for Applying Simple Filters

    This topic covers the following information:

    Statement Hierarchy for Applying Simple Filters

    You can apply a simple filter to the IPv4 ingress traffic at a logical interface by including the simple-filter input simple-filter-name statement at the [edit interfaces interface-name unit unit-number family inet] hierarchy level.

    [edit]
    interfaces {interface-name {unit logical-unit-number {family inet {simple-filter {input filter-name;}}}}}

    Restrictions for Applying Simple Filters

    You can apply a simple filter to the ingress IPv4 traffic at a logical interface configured on the following hardware only:

    • Gigabit Ethernet intelligent queuing (IQ2) PICs installed on M120, M320, or T Series routers.
    • Enhanced Queuing Dense Port Concentrators (EQ DPCs) installed on MX Series routers.

    The following additional restrictions pertain to applying simple filters:

    • Simple filters are not supported on Modular Port Concentrator (MPC) interfaces, including Enhanced Queuing MPC interfaces.
    • Simple filters are not supported for interfaces in an aggregated-Ethernet bundle.
    • You can apply simple filters to family inet traffic only. No other protocol family is supported.
    • You can apply simple filters to ingress traffic only. Egress traffic is not supported.
    • You can apply only a single simple filter to a supported logical interface. Input lists are not supported.

    Published: 2013-02-21