    Display Power Supply Error Messages in the Chassis Daemon Log File

    Purpose

    To determine the details of the power supply error messages in the chassis daemon log file.

    Action

    To display power supply error messages in the chassisd log file, use the following command:

    user@host> show log chassisd | match pem

    Sample Output

    user@host> show log chassisd | match pem
    Jul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Amber LED Off [0x18]
    Jul 15 11:18:59 PEM#0 - Amber LED Off
    Jul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Green LED Off [0x1a]
    Jul 15 11:18:59 PEM#0 - Green LED Off
    Jul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Blue LED Off [0x16]
    Jul 15 11:18:59 PEM#0 - Blue LED Off
    Jul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Amber LED Off [0x18]
    Jul 15 11:18:59 PEM#1 - Amber LED Off
    Jul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Green LED Off [0x1a]
    Jul 15 11:18:59 PEM#1 - Green LED Off
    Jul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Blue LED Off [0x16]
    Jul 15 11:18:59 PEM#1 - Blue LED Off
    Jul 15 11:19:02 PEM#0 added
    Jul 15 11:19:02 reading PEM 0 initial state
    Jul 15 11:19:02 PEM#1 added
    Jul 15 11:19:02 reading PEM 1 initial state
    Jul 15 11:19:18 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breaker
    Jul 15 11:19:18 CHASSISD_SNMP_TRAP: SNMP trap: FRU failure: jnxFruContentsIndex 2, jnxFruL1Index 2, jnxFruL2Index 0, jnxFruL3Index 0, jnxFruName PEM 1, jnxFruType 7, jnxFruSlot 2, jnxFruOfflineReason 2, jnxFruLastPowerOff 0, jnxFruLastPowerOn 
    26221491, jnxFruPowerUpTime 1484
    Jul 15 11:19:23 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breaker
    Jul 15 11:19:28 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breaker
    Jul 15 11:19:33 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breaker
    Jul 15 11:19:38 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breaker
    

    Meaning

    The chassisd database provides the date, time, and a component status message. The chassisd database is dynamic. It is initialized at router startup and is updated when components are added or removed.

     