Display Power Supply Error Messages in the Chassis Daemon Log File
Purpose
To determine the details of the power supply error messages in the chassis daemon log file.
Action
To display power supply error messages in the chassisd log file, use the following command:
user@host> show
log chassisd | match pem
Sample Output
user@host> show log chassisd | match pem Jul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Amber LED Off [0x18] Jul 15 11:18:59 PEM#0 - Amber LED Off Jul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Green LED Off [0x1a] Jul 15 11:18:59 PEM#0 - Green LED Off Jul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Blue LED Off [0x16] Jul 15 11:18:59 PEM#0 - Blue LED Off Jul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Amber LED Off [0x18] Jul 15 11:18:59 PEM#1 - Amber LED Off Jul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Green LED Off [0x1a] Jul 15 11:18:59 PEM#1 - Green LED Off Jul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Blue LED Off [0x16] Jul 15 11:18:59 PEM#1 - Blue LED Off Jul 15 11:19:02 PEM#0 added Jul 15 11:19:02 reading PEM 0 initial state Jul 15 11:19:02 PEM#1 added Jul 15 11:19:02 reading PEM 1 initial state Jul 15 11:19:18 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breaker Jul 15 11:19:18 CHASSISD_SNMP_TRAP: SNMP trap: FRU failure: jnxFruContentsIndex 2, jnxFruL1Index 2, jnxFruL2Index 0, jnxFruL3Index 0, jnxFruName PEM 1, jnxFruType 7, jnxFruSlot 2, jnxFruOfflineReason 2, jnxFruLastPowerOff 0, jnxFruLastPowerOn 26221491, jnxFruPowerUpTime 1484 Jul 15 11:19:23 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breaker Jul 15 11:19:28 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breaker Jul 15 11:19:33 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breaker Jul 15 11:19:38 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breaker
Meaning
The chassisd database provides the date, time, and a component status message. The chassisd database is dynamic. It is initialized at router startup and is updated when components are added or removed.
Related Documentation