Related Documentation
- M Series
- Power Supplies Overview
- MX Series
- Power Supplies Overview
- T Series
- Power Supplies Overview
Check the Power Supply Environmental Status
Purpose
To isolate problems by checking the environmental status of the power supply.
Action
To check the power supply environmental status, use the following operational mode command:
Sample Output
For M5, M10, M20, and M40 routers:
user@host> show chassis environment
Class Item Status Measurement
Power Power Supply A OK
Power Supply B Absent
[...Output truncated...]
For M7i and M10i routers:
user@host> show chassis environment
Class Item Status Measurement
Power Power Supply 0 OK
Power Supply 1 Absent
[...Output truncated...]
For M40e, M160, M320 and T320 , T640, T1600, TX Matrix, and TX Matrix Plus routers:
user@host> show chassis environment
Class Item Status Measurement
Power PEM 0 OK
PEM 1 OK
[...Output truncated...]
Meaning
The command output displays the status of both power supplies installed in the router.
For M5, M10, M7i, M10i, M20, and M40 routers, the command output displays the power supply slot number and status. The status can be OK, Testing (during initial power-on), Failed, or Absent. A Failed condition triggers the red alarm LED on the craft interface.
For M40e, M120, M160, M320, T320, T640, and T1600 routers, the output displays the power supply slot number and status for the Power Entry Modules (PEMs). The status can be OK, Absent, or Check.
For the M40e, M120, M160, M320, T320, T640, T1600, TX Matrix, and TX Matrix Plus routers, to display the power supply status, use the following command:
user@host> show chassis environment pem PEM 0 status:
State Online
Temperature OK
DC input OK
DC output OK
Load Less than 20 percent
Voltage:
48.0 V input 69028 mV
48.0 V fan supply 48839 mV
5.0 V bias 5013 mV
8.0 V bias 8253 mV
PEM 1 status:
State Online
Temperature OK
DC input OK
DC output OK
Load Less than 20 percent
Voltage:
48.0 V input 69307 mV
48.0 V fan supply 49170 mV
5.0 V bias 4991 mV
8.0 V bias 8263 mV
For each PEM, the command output displays the slot number, status, temperature, DC input and output, load percentage, and voltage. You can display the status of a particular power supply by specifying the slot number.
For T320, T640, T1600, TX Matrix, and TX Matrix Plus routers, the command output displays the PEM slot number, status, temperature, DC input status, and DC output for each Flexible PIC Concentrator (FPC), SONET Clock Generator (SCG), Control Board, and Switch Interface Board (SIB). You can display the status of a particular power supply by specifying the slot number.
user@host> show chassis environment pem PEM 1 status:
State Online
Temperature 33 degrees C / 91 degrees F
DC input: OK
DC Output: Voltage Current Power Load
FPC 0 53783 3368 181 24
FPC 1 0 0 0 0
FPC 2 0 0 0 0
FPC 3 0 0 0 0
FPC 4 54041 3462 187 24
FPC 5 53883 5187 279 37
FPC 6 0 0 0 0
FPC 7 0 0 0 0
SCG/CB/SIB 54066 4031 217 18