Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All
     

    Related Documentation

     

    Check the Power Supply Environmental Status

    Purpose

    To isolate problems by checking the environmental status of the power supply.

    Action

    To check the power supply environmental status, use the following operational mode command:

    user@host> show chassis environment

    Sample Output

    For M5, M10, M20, and M40 routers:

    user@host>  show chassis environment
    Class Item                   Status     Measurement
    Power Power Supply A         OK
          Power Supply B         Absent
    [...Output truncated...]
    

    For M7i and M10i routers:

    user@host>  show chassis environment
    Class Item                   Status     Measurement
    Power Power Supply 0         OK
          Power Supply 1         Absent
    [...Output truncated...]
    

    For M40e, M160, M320 and T320 , T640, T1600, TX Matrix, and TX Matrix Plus routers:

    user@host>  show chassis environment
    Class Item                   Status     Measurement
    Power PEM 0                  OK        
          PEM 1                  OK        
    [...Output truncated...]
    

    Meaning

    The command output displays the status of both power supplies installed in the router.

    For M5, M10, M7i, M10i, M20, and M40 routers, the command output displays the power supply slot number and status. The status can be OK, Testing (during initial power-on), Failed, or Absent. A Failed condition triggers the red alarm LED on the craft interface.

    For M40e, M120, M160, M320, T320, T640, and T1600 routers, the output displays the power supply slot number and status for the Power Entry Modules (PEMs). The status can be OK, Absent, or Check.

    For the M40e, M120, M160, M320, T320, T640, T1600, TX Matrix, and TX Matrix Plus routers, to display the power supply status, use the following command:

    user@host> show chassis environment pem
    PEM 0 status:
      State                       Online
      Temperature                 OK
      DC input                    OK
      DC output                   OK
      Load                        Less than 20 percent
      Voltage:
        48.0 V input        69028 mV
        48.0 V fan supply   48839 mV
        5.0 V bias           5013 mV
        8.0 V bias           8253 mV
    PEM 1 status:
      State                       Online
      Temperature                 OK
      DC input                    OK
      DC output                   OK
      Load                        Less than 20 percent
      Voltage:
        48.0 V input        69307 mV
        48.0 V fan supply   49170 mV
        5.0 V bias           4991 mV
        8.0 V bias           8263 mV
    

    For each PEM, the command output displays the slot number, status, temperature, DC input and output, load percentage, and voltage. You can display the status of a particular power supply by specifying the slot number.

    For T320, T640, T1600, TX Matrix, and TX Matrix Plus routers, the command output displays the PEM slot number, status, temperature, DC input status, and DC output for each Flexible PIC Concentrator (FPC), SONET Clock Generator (SCG), Control Board, and Switch Interface Board (SIB). You can display the status of a particular power supply by specifying the slot number.

    user@host> show chassis environment pem
    PEM 1 status:
      State                           Online
      Temperature                  33 degrees C / 91 degrees F
      DC input:                       OK
      DC Output:            Voltage   Current       Power    Load
           FPC 0              53783      3368         181      24
           FPC 1                  0         0           0       0
           FPC 2                  0         0           0       0
           FPC 3                  0         0           0       0
           FPC 4              54041      3462         187      24
           FPC 5              53883      5187         279      37
           FPC 6                  0         0           0       0
           FPC 7                  0         0           0       0
      SCG/CB/SIB              54066      4031         217      18 
    
     

    Related Documentation

     

    Published: 2012-08-20