Configuring the PPP Clear Loop Detected Timer
When a Point-to-Point Protocol (PPP) session detects a loop, the loop detected flag is set. If the flag is not cleared by the protocol after the loopback is cleared, the clear loop detected timer clears the flag after the specified time has elapsed.
To configure the clear loop detected timer for the LCP component of a PPP session, include the loopback-clear-timer statement, and specify the number of seconds.
loopback-clear-timer seconds;
You can include this statement at the following hierarchy levels:
- [edit interfaces interface-name unit logical-unit-number ppp-options]
- [edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number ppp-options]
To monitor the configuration, issue the show interfaces interface-name extensive command.