Pathfinder Applications
Note: † Internal applications are hidden from customers and partners. This is visible to you because you have logged into HPEs internal network.
Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Configuring Link PIC Failover on Channelized OC3 IQ and IQE Interfaces
For Channelized OC3 IQ or IQE PICs used as linking PICs in redundant LSQ configurations, you can inhibit the router from sending PPP termination-request messages to the remote host if the link PIC fails. To do this, include the no-termination-request statement at the [edit interfaces interface-name ppp-options] hierarchy level:
The no-termination-request statement is supported only with MLPPP and SONET APS configurations and works with PPP, PPP over Frame Relay, and MLPPP interfaces only.
For information about interchassis and intrachassis LSQ failover, see the Junos Services Interfaces Configuration Release 12.3.