vci-range
Syntax
vci-range start start-vci end end-vci;
Hierarchy Level
[edit interfaces at-fpc/pic/port unit logical-unit-number],[edit logical-systems logical-system-name interfaces at-fpc/pic/port unit logical-unit-number]
Release Information
Statement introduced in Junos OS Release 9.0.
Description
Range of VCI values used in ATM-to-Ethernet interworking cross-connects. VCI 0 through 31 are reserved. VCI 0 through 31 should not be used.
Options
start-vci—Lowest number VCI in the range.
end-vci—Highest number VCI in the range.
Range: 0 through 255
Required Privilege Level
interface—To view this statement in the configuration.