Pathfinder Applications
Note: † Internal applications are hidden from customers and partners. This is visible to you because you have logged into HPEs internal network.
Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Related Documentation
- ACX Series
- Configuring Threshold Values for Local Fault Events on an Interface
- Configuring Threshold Values for Fault Events in an Action Profile
- M Series
- Configuring Threshold Values for Local Fault Events on an Interface
- Configuring Threshold Values for Fault Events in an Action Profile
- MX Series
- Configuring Threshold Values for Local Fault Events on an Interface
- Configuring Threshold Values for Fault Events in an Action Profile
- T Series
- Configuring Threshold Values for Local Fault Events on an Interface
- Configuring Threshold Values for Fault Events in an Action Profile
symbol-period
Syntax
symbol-period count;
Hierarchy Level
[edit protocols oam ethernet link-fault-management action-profile event, link-event-rate],[edit protocols oam link-fault-management interface interface-name event-thresholds]
Release Information
Statement introduced in Junos OS Release 8.4.
Description
Configure the threshold for sending symbol period events or taking the action specified in the action profile.
A symbol error is any symbol code error on the underlying physical layer. The symbol period threshold is reached when the number of symbol errors reaches the configured value within the period window. The default period window is the number of symbols that can be transmitted on the underlying physical layer in 1 second. The window is not configurable.
Options
count—Threshold count for symbol period events.
Range: 1 through 100
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related Documentation
- ACX Series
- Configuring Threshold Values for Local Fault Events on an Interface
- Configuring Threshold Values for Fault Events in an Action Profile
- M Series
- Configuring Threshold Values for Local Fault Events on an Interface
- Configuring Threshold Values for Fault Events in an Action Profile
- MX Series
- Configuring Threshold Values for Local Fault Events on an Interface
- Configuring Threshold Values for Fault Events in an Action Profile
- T Series
- Configuring Threshold Values for Local Fault Events on an Interface
- Configuring Threshold Values for Fault Events in an Action Profile