startup-alarm
Syntax
startup-alarm (falling-alarm | rising-alarm | rising-or-falling-alarm);
Hierarchy Level
[edit snmp rmon alarm index]
Release Information
Statement introduced before Junos OS Release 7.4.
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Description
The alarm that can be sent upon entry startup.
Options
falling-alarm—Generated if the first sample after the alarm entry becomes active is less than or equal to the falling threshold.
rising-alarm—Generated if the first sample after the alarm entry becomes active is greater than or equal to the rising threshold.
rising-or-falling-alarm—Generated if the first sample after the alarm entry becomes active satisfies either of the corresponding thresholds.
Default: rising-or-falling-alarm
Required Privilege Level
snmp—To view this statement in the configuration.
snmp-control—To add this statement to the configuration.