    revert-time (Interfaces)

    Syntax

    revert-time seconds;

    Hierarchy Level

    [edit interfaces interface-name sonet-options aps]

    Release Information

    Statement introduced before Junos OS Release 7.4.

    Description

    Configure APS revertive mode.

    Default

    APS operates in nonrevertive mode.

    Options

    seconds—Amount of time to wait after the working circuit has again become functional before making the working circuit active again.

    Range: 1 through 65,535 seconds

    Default: None (APS operates in nonrevertive mode)

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration.