quality-level (hybrid)
Syntax
quality-level (prs | st2 | tnc | st3e | st3 | smc | st4)
| (prc | ssu-a | ssu-b | sec);
Hierarchy Level
[edit protocols ptp slave clock-class-to-quality-level-mapping]
Release Information
Statement introduced in Junos OS Release 12.2R2.
Description
Configure the quality level for the timing source so that the router knows the best available source with which to synchronize. The quality level specifies the accuracy level of the clock.
Options
prs —Primary reference source—Stratum 1
st2—Stratum 2
tnc—Transit node clock
st3e—Stratum 3E
st3—Stratum 3
smc—SONET minimum clock
st4—Stratum 4
prc—Primary reference clock
ssu-a—Synchronization supply unit A
ssu-b—Synchronization supply unit B
sec—SDH equipment clock
Required Privilege Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Related Documentation
- ACX Series
- Precision Time Protocol Overview
- Synchronous Ethernet Overview
- MX Series
- Configuring Hybrid Mode and ESMC Quality Level Mapping
- Example: Configuring Hybrid Mode and ESMC Quality Level Mapping
- Understanding Hybrid Mode
- Precision Time Protocol Overview
- Synchronous Ethernet Overview
- PTX Series
- Synchronous Ethernet Overview