    passive-monitor-mode

    Syntax

    passive-monitor-mode;

    Hierarchy Level

    [edit interfaces interface-name],[edit interfaces interface-name unit logical-unit-number],[edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number]

    Release Information

    Statement introduced before Junos OS Release 7.4.

    Description

    Monitor packet flows from another router. If you include this statement in the configuration, the interface does not send keepalives or alarms, and does not participate actively on the network.

    This statement is supported on ATM, Ethernet, and SONET/SDH interfaces. For more information, see the Junos OS ATM Interfaces Configuration Guide and Junos OS ATM Interfaces Configuration Guide.

    For ATM and Ethernet interfaces, you can include this statement on the physical interface only.

    For SONET/SDH interfaces, you can include this statement on the logical interface only.

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration.

    Published: 2013-02-13