    minimum-links

    Syntax

    minimum-links number;

    Hierarchy Level

    [edit interfaces aex aggregated-ether-options], [edit interfaces aex aggregated-sonet-options],[edit interfaces interface-name mlfr-uni-nni-bundle-options],[edit interfaces interface-name unit logical-unit-number],[edit interfaces interface-range range aggregated-ether-options],[edit interfaces interface-range range aggregated-sonet-options],[edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number]

    Release Information

    Statement introduced before Junos OS Release 7.4.

    Statement introduced in Junos OS Release 9.0 for EX Series switches.

    Description

    For aggregated Ethernet, SONET/SDH, multilink, link services, and voice services interfaces only, set the minimum number of links that must be up for the bundle to be labeled up.

    Options

    number—Number of links.

    Range: On M120, M320, MX Series, T Series, and TX Matrix routers with Ethernet interfaces, the valid range for minimum-links number is 1 through 16. When the maximum value (16) is specified, all configured links of a bundle must be up for the bundle to be labeled up.

    On all other routers and on EX Series switches, other than EX8200 switches, the range of valid values for minimum-links number is 1 through 8. When the maximum value (8) is specified, all configured links of a bundle must be up for the bundle to be labeled up

    On EX8200 switches, the range of valid values for minimum-links number is 1 through 12. When the maximum value (12) is specified, all configured links of a bundle must be up for the bundle to be labeled up.

    Default: 1