Related Documentation
- ACX Series
- Example: Configuring BFD for Static Routes
- minimum-interval
- threshold
- EX Series
- bfd-liveness-detection
- minimum-interval
- threshold
- J Series
- Example: Configuring BFD for Static Routes
- M Series
- Example: Configuring BFD for Static Routes
- bfd-liveness-detection
- minimum-interval
- threshold
- MX Series
- Example: Configuring BFD for Static Routes
- bfd-liveness-detection
- minimum-interval
- threshold
- PTX Series
- bfd-liveness-detection
- QFabric System
- threshold
- QFX Series standalone switches
- Example: Configuring BFD for Static Routes
- minimum-interval
- threshold
- SRX Series
- Example: Configuring BFD for Static Routes
- bfd-liveness-detection
- minimum-interval
- threshold
- T Series
- Example: Configuring BFD for Static Routes
- bfd-liveness-detection
- minimum-interval
- threshold
minimum-interval (BGP BFD Transmit Interval)
Syntax
Hierarchy Level
Release Information
Statement introduced in Junos OS Release 8.2.
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Support for BFD authentication introduced in Junos OS Release 9.6.
Statement introduced in Junos OS Release 12.1 for the QFX Series.
Description
Configure the minimum interval at which the local routing device transmits hello packets to a neighbor with which it has established a BFD session. Optionally, instead of using this statement, you can configure the minimum transmit interval using the minimum-interval statement.
Options
milliseconds—Minimum transmit interval value.
Range: 1 through 255,000
![]() | Note: The threshold value specified in the threshold statement must be greater than the value specified in the minimum-interval statement for the transmit-interval statement. |
Required Privilege Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Related Documentation
- ACX Series
- Example: Configuring BFD for Static Routes
- minimum-interval
- threshold
- EX Series
- bfd-liveness-detection
- minimum-interval
- threshold
- J Series
- Example: Configuring BFD for Static Routes
- M Series
- Example: Configuring BFD for Static Routes
- bfd-liveness-detection
- minimum-interval
- threshold
- MX Series
- Example: Configuring BFD for Static Routes
- bfd-liveness-detection
- minimum-interval
- threshold
- PTX Series
- bfd-liveness-detection
- QFabric System
- threshold
- QFX Series standalone switches
- Example: Configuring BFD for Static Routes
- minimum-interval
- threshold
- SRX Series
- Example: Configuring BFD for Static Routes
- bfd-liveness-detection
- minimum-interval
- threshold
- T Series
- Example: Configuring BFD for Static Routes
- bfd-liveness-detection
- minimum-interval
- threshold
