mc-ae
Syntax
Hierarchy Level
Release Information
Statement introduced in Junos OS Release 9.6.
events statement introduced in Junos OS Release 11.4R4.
Description
Enable Multichassis Link Aggregation (MC-LAG ), which allows one device to form a logical LAG interface with two or more other devices.
Options
chassis-id | — | Specify the chassis ID for Link Aggregation Control Protocol (LACP) to calculate the port number of MC-LAG physical member links. |
Values: 0 | 1
events | — | Specify an action if a specific MC-LAG event occurs.
|
mc-ae-id | — | Specify the identification number of the MC-LAG device. The two MC-LAG network devices that manange a given MC-LAG must have the same identification number. |
Range: 1 through 65535
mode (active-active | active-standby) | — | Specify whether the MC-LAG is in active-active or active-standby mode. |
redundancy-group | — | Specify the redundancy group identification number. The Inter-Chassis Control Protocol (ICCP) uses the redundancy group ID to associate multiple chassis that perform similar redundancy functions. |
Range: 1 through 4294967294
status-control (active | standby) | — | Specify whether the chassis becomes active or remains in standby when an interchassis link failure occurs. |
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.