    max-duplicates

    Syntax

    max-duplicates number;

    Hierarchy Level

    [edit services dynamic-flow-capture capture-group client-name]

    Release Information

    Statement introduced in Junos OS Release 9.2.

    Description

    Specify the maximum number of content destinations to which the DFC PIC can send data from a single input set of packets. Limiting the number of duplicates reduces the load on the PIC. This setting overrides the globally applied g-max-duplicates setting.

    Default

    If no value is configured, a default setting of 3 is used.

    Options

    number—Maximum number of content destinations.

    Range: 1 through 64

    Usage Guidelines

    See Limiting the Number of Duplicates of a Packet.

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration.

     

    Related Documentation

     

    Published: 2013-02-15