    long-buildout

    Syntax

    (long-buildout | no-long-buildout);

    Hierarchy Level

    [edit interfaces interface-name t3-options]

    Release Information

    Statement introduced before Junos OS Release 7.4.

    Description

    Configure the T3 line buildout. A T3 interface has two settings for the T3 line buildout: a short setting, which is less than 255 feet (68 meters), and a long setting, which is greater than 255 feet and shorter than 450 feet (137 meters).

    This statement applies to copper-cable-based T3 interfaces only. You cannot configure a line buildout for a DS3 channel on a channelized OC12 interface, which runs over fiber-optic cable.

    Default

    A T3 interface uses the short line buildout setting (no-long-buildout) for wires shorter than 255 feet (68 meters).

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration.