Pathfinder Applications
Note: † Internal applications are hidden from customers and partners. This is visible to you because you have logged into HPEs internal network.
Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Related Documentation
lmi (Frame Relay)
Syntax
lmi {lmi-type (ansi | itu | c-lmi);n391dte number;n392dce seconds;n392dte number;n393dce number;n393dte number;t391dte number;t392dce seconds;}
Hierarchy Level
[edit interfaces interface-name]
Release Information
Statement introduced before Junos OS Release 7.4.
Description
Set Frame Relay keepalive parameters.
Options
n391dte—DTE full status polling interval.
Range: 1 through 255
Default: 6
n392dce—DCE error threshold, in number of errors.
Range: 1 through 10
Default: 3
n392dte—DTE error threshold, in number of errors.
Range: 1 through 10
Default: 3
n393dce—DCE monitored event-count.
Range: 1 through 10
Default: 4
n393dte—DTE monitored event-count.
Range: 1 through 10
Default: 4
t391dte—DTE polling timer.
Range: 5 through 30 seconds
Default: 10 seconds
t392dce—DCE polling timer.
Range: 5 through 30 seconds
Default: 15 seconds
The remaining statements are explained separately.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.