Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    link-down

    Syntax

    link-down (red | yellow | ignore);

    Hierarchy Level

    [edit chassis alarm ethernet],[edit chassis alarm fibre-channel],[edit chassis interconnect-device name alarm ethernet],[edit chassis node-group name alarm fibre-channel]

    Release Information

    Statement introduced in Junos OS Release 11.3 for the QFX Series.

    Description

    Specify either red, yellow, or ignore to display when the link is down.

    Options

    red
    —

    Indicates that one or more hardware components have failed or exceeded temperature thresholds, or an alarm condition configured on an interface has triggered a critical warning.

    yellow
    —

    Indicates a noncritical condition on the device that, if left unchecked, might cause an interruption in service or degradation in performance. A yellow alarm condition requires monitoring or maintenance.

    ignore
    —

    Suppresses or ignores the alarm.

    Required Privilege Level

    routing—To view this statement in the configuration.
    routing-control—To add this statement to the configuration.

    Published: 2013-08-15