    interval (RMON)

    Syntax

    interval seconds;

    Hierarchy Level

    [edit snmp rmon alarm index],[edit snmp rmon history index]

    Release Information

    Statement introduced in Junos OS Release 11.1 for the QFX Series.

    Description

    Configure the interval over which data is to be sampled for the specified alarm or interface.

    Default

    60 sec for alarm sampling.

    1800 sec for history sampling.

    Options

    seconds—Interval at which data is to be sampled for the specified alarm or interface.

    Required Privilege Level

    snmp—To view this statement in the configuration.
    snmp–control—To add this statement to the configuration.

    Published: 2013-08-09