Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    hold-time (SONET/SDH Defect Triggers)

    Syntax

    hold-time up milliseconds down milliseconds;

    Hierarchy Level

    [edit interfaces interface-name sonet-options trigger defect]

    Release Information

    Statement introduced before Junos OS Release 7.4.

    Description

    For ATM over SONET/SDH and SONET/SDH interfaces only, apply up and down hold times to SONET/SDH defect triggers. When you apply a down hold time to a defect, the defect must remain present for at least the hold-time period before the interface is marked down. When you apply an up hold time to a defect, the defect must remain absent for at least the hold-time period before the interface is marked up, assuming no other defect is outstanding.

    • When up or down hold times are applied to SONET defect triggers of a 10-Gigabit Ethernet WAN-PHY interface, only the defects generated in the WAN Interface Sublayer (WIS) are damped. Therefore, if the hold times are applied to SONET defect triggers only, a 10-Gigabit Ethernet WAN-PHY interface might be marked up or down because of the faults that are generated in other layers, such as the Physical Coding Sublayer (PCS) or Physical Medium Attachment Sublayer (PMA), 10 Gigabit Media Independent Interface (XGMII) Extender Sublayer (XGXS), and Media Access Control (MAC). To damp the interface up or down events of a 10-Gigabit Ethernet WAN-PHY interface, you need to apply up or down hold-times for the interface at the [edit interfaces interface-name] hierarchy level.
    • On M Series and T Series platforms with Channelized SONET IQ PICs and Channelized SONET IQE PICs, the SONET defect alarm trigger hold-time statement is not supported.

    Default

    If you do not include this statement, when a defect is detected the interface is marked down immediately, and when the defect becomes absent the interface is marked up immediately.

    Options

    down milliseconds—Hold time to wait before the interface is marked down.

    Range: 1 through 65,534 milliseconds

    Default: No hold time

    up milliseconds—Hold time to wait before the interface is marked up.

    Range: 1 through 65,534 milliseconds

    Default: No hold time

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration.

    Published: 2013-02-13