Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    frame-period-summary

    Syntax

    frame-period-summary count;

    Hierarchy Level

    Release Information

    Statement introduced in Junos OS Release 8.4.

    Description

    Threshold for sending frame period summary error events or taking the action specified in the action profile.

    An errored frame second is any 1-second period that has at least one errored frame. This event is generated if the number of errored frame seconds is equal to or greater than the specified threshold for that period window. The default window is 60 seconds. The window is not configurable.

    Options

    count—Threshold count for frame period summary error events.

    Range: 1 through 100

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration.