    fcs

    Syntax

    fcs (16 | 32);

    Hierarchy Level

    [edit interfaces e1-fpc/pic/port],[edit interfaces t1-fpc/pic/port],[edit interfaces interface-name ds0-options],[edit interfaces interface-name e1-options],[edit interfaces interface-name e3-options],[edit interfaces interface-name sonet-options],[edit interfaces interface-name t1-options],[edit interfaces interface-name t3-options]

    Release Information

    Statement introduced before Junos OS Release 7.4.

    Statement introduced in Junos OS Release 12.2 for the ACX Series Universal Access Routers.

    Description

    For E1/E3, SONET/SDH, and T1/T3 interfaces, configure the frame checksum (FCS) on the interface. The checksum must be the same on both ends of the interface.

    On a channelized OC12 interface, the SONET/SDH fcs statement is not supported. To configure FCS on each DS3 channel, you must include the t3-options fcs statement in the configuration for each channel. For SONET/SDH, the channelized OC12 interface supports DS3 to STS-1 to OC12. For SDH, the channelized OC12 interface supports NxDS3 to NxVC3 to AU3 to STM.

    Note: When configuring E1 or T1 interfaces on 10-port Channelized E1/T1 IQE PICs, the fcs statement must be included at the [edit interfaces e1-fpc/pic/port] or [edit interfaces t1-fpc/pic/port] hierarchy level as appropriate.

    Options

    16—Use a 16-bit frame checksum on the interface.

    32—Use a 32-bit frame checksum on the interface. Using a 32-bit checksum provides more reliable packet verification, but some older equipment might not support 32-bit checksums.

    Default: 16

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration.

    Published: 2013-02-13