    flow-detect-time (DDoS Flow Detection)

    Syntax

    flow-detect-time seconds;

    Hierarchy Level

    [edit system ddos-protection protocols protocol-group packet-type flow-detection]

    Release Information

    Statement introduced in Junos OS Release 12.3.

    Description

    (MX Series routers with MPCs only) Configure how much time must pass before a suspicious flow that has exceeded the bandwidth allowed for the packet type is confirmed to be a culprit flow.

    Best Practice: We recommend that you use the default value for the detection period.

    Options

    seconds—Period of excessive bandwidth required for flow to be a culprit flow.

    Range: 1 through 60 seconds

    Default: Three seconds

    Required Privilege Level

    admin—To view this statement in the configuration.

    admin-control—To add this statement to the configuration.