Pathfinder Applications
Note: † Internal applications are hidden from customers and partners. This is visible to you because you have logged into HPEs internal network.
Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Related Documentation
crc-major-alarm-threshold
Syntax
crc-major-alarm-threshold (1e-3 | 5e-4 | 1e-4 | 5e-5 |
1e-5);
Hierarchy Level
[edit interfaces interface-name t1-options]
Release Information
Statement introduced in Junos OS Release 8.5.
Statement introduced in Junos OS Release 12.2 for the ACX Series Universal Access Routers.
Description
Major alarm error thresholds for T1 CRC errors. When the threshold is exceeded for one second, a defect condition is declared. If the defect condition continues for the monitoring period, an alarm condition is declared.
Default
10-second monitoring period for all settings except 1e-5. The 1e-5 value uses a 50-second monitoring period.
Options
rate—Error rate expressed as the number of errors per number of bits. The value 1e-3 is one error in 10-3 bits and 5e-4 is five errors in 10-4 bits.
Default: 5e-5
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.