advertise-interval
Syntax
advertise-interval milliseconds;
Hierarchy Level
[edit interfaces interface-name sonet-options aps]
Release Information
Statement introduced before Junos OS Release 7.4.
Description
Modify the Automatic Protection Switching (APS) interval at which the protect and working routers send packets to their neighbors to advertise that they are operational. A router considers its neighbor to be operational for a period, called the hold time, that is, by default, three times the advertisement interval.
Options
milliseconds—Interval between advertisement packets.
Range: 1 through 65,534 milliseconds
Default: 1000 milliseconds