Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    request chassis sib

    Syntax

    request chassis sib (offline | online) slot slot-number

    Syntax (TX Matrix Router)

    request chassis sib (all-chassis | lcc number | scc) (offline | online) slot slot-number(start-receiver number | stop-receiver number)

    Syntax (TX Matrix Plus Router)

    request chassis sib (all-lcc | f13 slot-number | f2s sib-slot/sib-f2s-slot-number |lcc number  | (offline | online) slot slot-number)

    Release Information

    Command introduced before Junos OS Release 7.4.

    f13 and f2s options for the TX Matrix Plus router introduced in Junos OS Release 9.6.

    Description

    (M320 routers and T Series routers only) Control the operation of the specified Switch Interface Board (SIB).

    Options

    all-chassis
    —

    (TX Matrix routers only) Control the status of the specified SIB.

    all-lcc
    —

    (TX Matrix Plus router only) On TX Matrix Plus router, control the operation of the SIB on all routers connected to the TX Matrix Plus router.

    f13 slot-number
    —

    Control the operation of F13 SIBs. Replace slot-number with a value 0, 1, 3, 4, 6, 7, 8, 9, 11, or 12.

    f2s sib-slot/sib-f2s-slot-number
    —

    (TX Matrix Plus routers only) (Optional) Control the operation of the SIB F2s. Replace sib-slot with a value from 0 through 4, followed by a sib-f2s-slot-number value 0, 2, 4 or 6.

    lcc number
    —

    (TX Matrix router and TX Matrix Plus router only) (Optional) Line-card chassis number.

    Replace number with the following values depending on the LCC configuration:

    • 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.
    • 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.
    • 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.
    • 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.
    scc
    —

    (TX Matrix router only) TX Matrix router (switch-card chassis) on a routing matrix.

    offline
    —

    Take the SIB offline.

    online
    —

    Bring the SIB online.

    slot slot-number
    —

    SIB slot number. For the T320 router, replace slot-number with a value from 0 through 2. For the T640 router, TX Matrix router, and T1600 router in a routing matrix, replace slot-number with a value from 0 through 4.

    start-receiver number
    —

    (TX Matrix routers only) Start the SIB optical receiver. Replace number with a value from 0 through 3.

    stop-receiver number
    —

    (TX Matrix routers only) Stop the SIB optical receiver. Replace number with a value from 0 through 3.

    Required Privilege Level

    maintenance

    List of Sample Output

    request chassis sib
    request chassis sib

    Output Fields

    When you enter this command, you are provided feedback on the status of your request.

    Sample Output

    request chassis sib

    user@host> request chassis sib slot 0 online
    Online initiated, use "show chassis sibs" to verify
    

    request chassis sib

    user@host> request chassis sib f13 slot 0 offline
    Offline initiated, use "show chassis sibs" to verify
    

    Published: 2013-03-14